Over time, this water can build up and cause the trap to become clogged. To clean the condensate trap, you will need to first shut off the power to the unit. Navien condensing technology provides up to 0.96 UEF. It has a condensation drip spout, and drips about 1 gallon of water per day. Everything is good, I installed the proper intake an exhaust with 3in schedule 40 PVC pipes as recommended, I plumbed 3/4in copper pipes for cold and hot water, a 3/4in gas line. It is important to keep this fitting clean and free of any debris, as it can clog and cause problems with the units operation. If you need to replace your Navien condensate trap o-ring, you can find the right one for your unit by checking the manual or contacting the manufacturer. Some people like to sleep there and have long conversations. Why would turning on/off hot water when the toilet is flushing cause the tankless pressure relief valve to release water? TomCare Detachable Hose Holder- It is convenient to move and store if necessary. Most technician said there might be a leak in the heat exchanger. Building owners or property managers appreciate the efficiency, reliability and durability of Navien tankless water heaters over outdated tank systems. Difference between "select-editor" and "update-alternatives --config editor". We hope this article helps you make the right call. This might involve cutting a hole in the exhaust pipe and attaching a hose to it. Error posting question. You should check your o-ring regularly and replace it if necessary. If that's an issue down the road, I've picked some PVC plastic fittings for the drain tube.The alkaline soap/detergent residue in a laundry drain will neutralize the slightly acidic condensate. We already mentioned why the condensate pipe has to be made of plastic and not metal due to the risk of corrosion. In my area, the water is slightly alkaline and the city doesn't require condensate neutralizers. Our payment security system encrypts your information during transmission. They were not helpful. I had the exact same problem. Some of it will condense on the heat exchanger. The condensate is a product of combustion of the hydrocarbon fuel: hydrocarbon + oxygen > carbon dioxide + water. I am planning the drain line (which will have a neutralizer on it to reduce the acidity). Home Improvement Stack Exchange is a question and answer site for contractors and serious DIYers. Where is the 2 internal drain valve in Navien 240a tankless water heater (damaged needs replacement), We've added a "Necessary cookies only" option to the cookie consent popup, Tankless water heater - not consistent hot water output, Correcting Navien Tankless Hot Water Heater Installation. But, as it is only a bit acidic, this poses no threat to health. We get it, but (1) terrylove.com can't live without ads, and (2) ad blockers can cause issues with videos and comments. Learn how your comment data is processed. Can the condensation line (using a condensate pump) of a basement hybrid water heater be connected to a waste line directly above the water heater? drain - Tankless water heater plumbing: neutralized condensate and I have called Navien and several plumbers and it seemed like nobody had a clue what was going on. Basic Maintenance of a Navien NPE A tankless water heater You can probably get it from a plumbing store, or order online. Protect the water supply and water heating equipment with eco-friendly water treatment solutions. Space-saving high-efficiency condensing boilers provide the ultimate heating and comfort experience. Since 2006, Navien, Inc. has become one of the fastest growing companies in the home comfort sector in North America and is now a leader in condensing technology, providing condensing tankless water heaters, combi-boilers, and boilers.*. Refrain from trying to fix the condensate trap by yourself because chances are, you will do more damage than good. Efficient and earth-friendly products designed for any size home. Blocked condensate traps are generally a result of not servicing your boiler for a long time. Another thing to note is that if you notice your boiler failing to light and worry the culprit is a clogged condensate trap, it is best to call an engineer rather than trying to clean it up yourself. Inside a condensing tankless water heater, the combustion process superheats the water that enters your shower, sink, etc. But did you know that your Navien tankless water heater can also produce condensate? rev2023.3.3.43278. It looks like you're using an ad blocker. This kits provide a simple and effective ways for AC draining the condensate. The condensate drain fitting is located on the bottom of the unit, and is made of PVC. You are using an out of date browser. Commercial solutions from the leader in condensing technology. Come join the discussion about tools, projects, builds, styles, scales, reviews, accessories, classifieds, and more! Tankless Water Heaters | Navien Drain Hose Fit most Ductless Mini Split Air Conditioner and Heat Pump Systems. Navien Condensate Trap Leaking: Reasons And Troubleshooting. Why is this sentence from The Great Gatsby grammatical? Efficient, durable and high-performance products for any commercial application. The Navien NPE-2 series is a line of high-efficiency condensing tankless water heaters featuring a user-friendly control panel. Your email address will not be published. It can damage anything prone to corrosion. A condensate pipe devoid of an auto-siphon may be shaped like a U.. Before installation or repairs begin, make sure your service specialist calls Navien's Technical Support Department while in front of your unit: 800-519-8794, option 2. Navien offers the industry's most advanced condensing tankless water heaters, condensing boilers and the first combi-boilers strong enough to support . The table below shows the minimum drain size for each model. Thank you jmon. Condensing gas tankless water heaters include a second heat exchanger which uses heat from the exhaust gas to preheat incoming cold water. However, its important to make sure that your condensate drain is clear and unobstructed so that the water can drain properly. There are several reasons why the water heater condensation occurs: The flue gases are cooled below their "dew point" when having the cold air supply. It goes without saying that water leaking from any part of your home is not ideal, let alone acidic water leakage. I know some desert soils are very alkaline and might neutralize acidic condensate quite well themselves. Only one quick shower read more A lot of water continuously flow through the condensation line even the heat exchanger is not operating. Seems like the water here is very hard. Space-saving high-efficiency condensing boilers provide the ultimate home heating and comfort experience. It helps to seal the trap and prevent water from leaking out. Non-condensing units have an efficiency rating of 0.81 UEF, which is still far more efficient than tank-style water heaters. Does the plug have an O-ring? Generally, Navien tankless water heater demands 4 hours for a successful installation. Before the condensate is expelled through the condensate pipe, the water is accumulated in the sump of the boiler. Asking for help, clarification, or responding to other answers. Your question might be answered by sellers, manufacturers, or customers who bought this product. Cost is in US dollars. The size of the drain will depend on the model of Navien tankless water heater you have. This has a number of advantages, it's more efficient as it recovers the heat as the water condenses (heater is rated 93% efficient). Boilers are susceptible to wear and tear over time like any other household appliance. To see our price, add these items to your cart. We have had another plumbing issue with a leaky tub faucet. February 2019 9-year-old Navien NR-240A, I recently started noticing constant flow out the condensate drain @ ~ 2gph when unit is fully off with no demand. The temperature of flue gases decreases rapidly during this process, going down to 50 from 130. Red Label Abrasives Vs. Just put calcium carbonate rocks in my condensate water pump or buy a whole condensate kit? ${cardName} not available for the seller you chose. link to Red Label Abrasives Vs. It only takes a minute to sign up. Another key factor to consider is the quality of life. Once the water has drained, plug the unit back in and turn it on. I used some brass parts I had laying around and picked up a $3.00 roll of clear tubing from the hardware store.I'll keep an eye on the brass fitting for signs of corrosion. Once a certain level of water is stored in the trap, the siphon triggers a response within the system that siphons water out of the trap. The leak can only be stopped when I close the cold water inlet. Enter your ZIP code below to find an installer or service provider for your Navien tankless water heater, boiler, or combi-boiler. You accept the use of cookies as described in our, How Condensing Tankless Water Heaters Work. Thanks for contributing an answer to Home Improvement Stack Exchange! What, if any, treatment is required before irrigation use will depend in part on your local conditions. Overview Ultra-high efficiency condensing tankless water heaters > NPEA2 Series > NPES2 Series High efficiency non-condensing tankless water heaters > NPNE Series > NPNU Series Combi-boilers Venting & Accessories | Rinnai NPE-180S There was a problem adding this item to Cart. [{"displayPrice":"$35.95","priceAmount":35.95,"currencySymbol":"$","integerValue":"35","decimalSeparator":".","fractionalValue":"95","symbolPosition":"left","hasSpace":false,"showFractionalPartIfEmpty":true,"offerListingId":"6cij%2FI6Lfn8ENDnJVFPS5KSATGTDDFvFqWYsWPaj3jbs4aiqyvL7Dsp3iLGSYGUgbsiwStGwtrWYwcXDMMkrIlurqWJc7380oTo%2BE4k6TuIQeV2us0GLtep1aYs2ENAqmcYYiz52U%2FJXQcjtz7WZ2ywQnetjyE4jwW8R8092iIEtsmNt8ZmdCRyE7K%2B%2FG4rv","locale":"en-US","buyingOptionType":"NEW"}]. Please try again later. Tankless Water Heaters High-efficiency condensing and non-condensing tankless water heaters offer endless hot water and reduce gas usage. Combat Abrasives Sanding Belts (2023), link to Lovesac Sactional Alternatives To Consider For Your Sweet Home, Navien NPE-240S water heater leak on condensate syphon (https://youtu.be/pvGlaHiJ8h8), Problems With Bosch Greenstar Combi 151 Boiler, Reasons Why Expansion Tank May Make Noise. Does A Tankless Water Heater Need A Condensate Drain? Navien's products possess state-of-the-art technology, high efficiency and reliable quality. In the toilet or sinks case, however, it is to prevent bad sewer odor from entering your home. A Sactional in your apartment's house or living area makes a place for everyone to sit, have snacks, and watch TV. Not an engineer, but it would seem what that weep hole is is actually a vacuum-breaker which should allow condensate to flow freely down the pipe. Navien Flow Sensor Tankless Water Heater 136 Amazon's Choice in Water Heaters 5 offers from $15.00 Navien 30012033B Dhw Flow Sensor 21 5 offers from $46.27 Navien WATER ADJUSTMENT VALVE, part 30008245A, for NPE-A model 25 Amazon's Choice in Faucet Valves 3 offers from $85.90 Navien Flame Rod Assembly NPE NCB Series Part 30012226A 76 How to tell which packages are held back due to phased updates. Model Number Minimum Drain Size (inches) It looks like you're using an ad blocker. By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. Space-saving high-efficiency condensing boilers provide the ultimate heating and comfort experience. If any particular ad is your REASON for blocking ads, please let us know. condensate drain for Navien tankless water heater, Plumbing Forum, Professional & DIY Advice, Navien NPE-240A - Temperature Fluctuations. There was defintley some backpressure of some sort and the vent eliminated it. The heat exchange can corrode which leads to small metal bits getting stuck in the trap and eventually clogging the condensate drain. Please try again. You have to make sure your Navien boiler receives servicing regularly in compliance with the manufacturers guidelines. Would you be able to post a picture of the modification you've made to your Navien? However, proper maintenance is required in order to achieve this lifespan. The steam then condenses on the cold water lines and drains back into the tankless water heater. You are using an out of date browser. Metal-based fittings cannot be used as the condensate itself is a bit acidic in nature and will corrode metal. Here are the website rules, as well as some tips for using this forum. Home Improvement Stack Exchange is a question and answer site for contractors and serious DIYers. That section of the drain coming off the condensate trap retaining just enough suction to prevent it from flowing. Ideal replacement part for most of air conditioner,the connector adapter to the air conditioner,the hose help drain out the wasted condensate water,the hose clamp adjust to fit, Reinforced Pool Discharge Hose With Various Sizes. Navien OEM O-Rings. Does anyone have any perspective on likely actual condensate volume? Humidity will have little to no effect. Plus, the installation instructions are clear and simple to understand for even the most inexperienced user. Difference between "select-editor" and "update-alternatives --config editor". I don't know if it's just an open port or if there some sort of valve or venturi involved. Natural Gas Tankless water heater condensate volume, We've added a "Necessary cookies only" option to the cookie consent popup, Tankless water heater plumbing: neutralized condensate and pressure relief valve. All Navien O-Rings are brand new in the original factory packaging and are guaranteed to fit and function properly. This is a good option if you dont want to deal with the water inside your home. Watching this less than 2 minutes video will explain the reason and fix it. They use less energy (and money) than traditional water heaters because they don't need to reheat the water over and over. ComfortFlow includes a buffer tank, recirculation pump and fine-tuned controls which resolve the cold water sandwich effect and flow rate issues common in other tankless water heaters. I have had the same issue with a lot of cold water coming out of the condensate drain. We dont share your credit card details with third-party sellers, and we dont sell your information to others. Test boiler water just for a baseline. A properly maintained boiler is less likely to display problems with the condensate trap. Brief content visible, double tap to read full content. The condensate trap is designed to catch any water that condenses inside the unit. 51 10K views 2 years ago Small drip coming from the condensate syphon trap for a Navien water heater. I live in a desert area with a very low humidity (<15% normally) so 2 GPH seems excessive to me. Space-saving high-efficiency condensing boilers provide the ultimate home heating and comfort experience. Non-condensing tankless water heaters have a single heat exchanger and do not recycle heat from the exhaust gas. Navien flow out condensate line Heating Help: The Wall Shipping cost, delivery date, and order total (including tax) shown at checkout. Navien Condensate Trap Leaking: Reasons And Troubleshooting It only takes a minute to sign up. The proven ultra-high-efficiency, eco-friendly, space-saving way to supply endless domestic hot water for homes and businesses. Setting up a drain tube for the condensate out of the tankless water heater to the existing laundry drain.The Takagi tankless water heater I installed is a condensing model. Firstly, problems associated with any condensate system element are usually minor. Is it usually possible to transfer credits for graduate courses completed during an undergrad degree in the US? A tankless water heater does not need a drain. Whether you need an endless supply of hot water, efficient home heating or both, Navien has the perfect energy efficient solutions. Navien NPE-240A condensate drain leak - Terry Love Plumbing Advice In general, in a string of multiplication is it better to multiply the big numbers or the small numbers first? Navien tankless water heaters have a lifespan of up to 20 years. I have a Tagaki T-H3-DV-N (Indoor) tankless hot water heater. In addition, the waters warmth can comfortably shift the ice if it starts to form. Can Martian regolith be easily melted with microwaves? High Efficiency Water Heaters & Boilers for Homes | Navien A nice experience could quickly turn into a stressful one. Resources | Partners Login | Become an NSS |Certifications |Parts List | Technical Support | Careers |Global Network |Warranty, All contents copyright Navien Inc. | About Navien |Contact Us | Terms of Use |Privacy Policy |CCPA |Notices, Ultra-high efficiency condensing tankless water heaters, High efficiency non-condensing tankless water heaters, You accept the use of cookies as described in our, Problem Solved: Gandy Installations Saves Customer Enough Space for a Refrigerator, Problem Solved: Steve Hosack of SC Hosack Plumbing Upgrades His Hair Stylist to Navien, Ways to save money on your water & electric bill. These fittings are designed specifically for Navien units, and will ensure that your unit operates properly and safely. Tankless water heaters have a condensate drain to properly drain the excess condensation produced by the second heat exchange unit installed inside of condensing tankless water heaters. Water heaters located in the garage may terminate on the garage floor with the same distance requirements. You might also want to CAREFULLY take some very fine wire or a toothpick and try and clean out the weep hole. Is a neutralizer necessary for tankless condensate? Maybe it was forgotten when maintenance was performed 9 months ago. As an Amazon Associate, I Earn From Qualifying Purchases. Please try again. When the heater is idle, expect none. They called Navien and unfortunately my serial number was never registered so Im told it isnt under warranty. The heating engineer will clear out the debris from the trap during this time, preventing the buildup of sediment. HotButton on-demand recirculation option with built-in controller. It seems that the condensate gets stuck in the syphon and overflows. Battery backup system for tankless gas water heater (outdoor install). Thats why you need to take steps to fix the situation. The 3 ft. tall drain standpipe affords the required air gap between the end of the drain and the level of the water in the P-trap. Making statements based on opinion; back them up with references or personal experience. Most technician said there might be a leak in the heat exchanger. When you do not need to use the item, such as in Winter, you can disassemble it easily and store it without taking too much space. Take the cover off and you can see 2 translucent silicone hoses that connect from the small drain valves to the condensate drain line. Navien Tankless Water Heater Condensate Drain - Heaterview Doesn't seem like you can have it both ways. This water is then drained away, keeping your Navien water heater clean and free of any build-up. One way is to simply open up the drain valve and let the water drain out. The only tool needed in the repair process is a screwdriver. If any particular ad is your REASON for blocking ads, please let us know. Connect and share knowledge within a single location that is structured and easy to search. Because the heat exchanger gets very hot, any water that comes into contact with it will instantly turn to steam. Yes, cold weather can affect your hot water heater. The best answers are voted up and rise to the top, Not the answer you're looking for? The condensate trap is made up of a few different parts, one of which is the o-ring. Cooler exhaust means you have a wider range of venting material options, including PVC and polypropylene. This ensures that there is a water barrier present between the combustion chambers and the condensate pipe of the boiler. Stack Exchange network consists of 181 Q&A communities including Stack Overflow, the largest, most trusted online community for developers to learn, share their knowledge, and build their careers. Could anyone please point me where I can find the 2 internal drain valve? How to use Slater Type Orbitals as a basis functions in matrix method correctly? (CPC- UPC 505.6 CPC & 505.4, 508.5 & 608.5). Learn more about our products for home owners. Thank you to everyone who posted here! So, it drains out through the condensate line. In one post with a similar issue, actually had to replace the 2 internal drain valve to fix the problem. However, keep in mind that this liquid can corrode certain materials such as mental. Tankless Water Heaters: A Buyer's Guide - This Old House T&P line must be looking downward with no threads on the end. If the condensate trap does not require cleaning, the heating engineer will take it out, thoroughly rinse it, and refill it before refitting it. Condensing technology reduces energy consumption and greenhouse gas emissions. It looks like WhatsApp is not installed on your phone. The condensate is a combustion byproduct, and will be determined almost entirely by how much the heater runs - when the heater is running, expect pretty much the rated output. Replaced it and the problem was resolved. Navien tankless water heater CR-240A is leaking I've had this Navien CR-240A for 7 years (The unit is longer under warranty). When the heater is idle, expect none. Save my name, email, and website in this browser for the next time I comment. The Takagi tankless water heater I installed is a condensing model. But, it if were clogged, why would condensate be leaking out of it? How to perform annual maintenance on your Navien instantaneous water heater. I have a tankless Navien water heater installed and it drips If it is going through a neutralizer, is there any issue with letting the water flow into landscaped areas to water plants? Boiler was unplugged at the time. The condensate is a combustion byproduct, and will be determined almost entirely by how much the heater runs - when the heater is running, expect pretty much the rated output. The O-ring between the flow sensor on the inlet was bad. I'm planning on piping it away from the heater closet (on outside of house). If you have a Navien tankless water heater, you know that one of the most important parts of the unit is the condensate trap. Over time, this water can build up and cause the trap to become clogged. When you turn on the tap, cold water enters the unit and is rapidly heated to the desired temperature. The good news is that the Navien tankless water heater is designed to handle this condensate and drain it away from the unit. If youre not sure how to do this, you can always contact a Navien service technician to help you out. You do not have to be concerned about that. However, not all of the water will turn to steam. Is it safe to tie a water heater pressure release pipe into an HVAC condensate drain line? Frozen Condensate Line: Recognizing, Preventing & Fixing It Ultra high-efficiency tankless water heatersalso known as condensing tanklessuse two heat exchangers to supply endless hot water when you turn on a faucet. Why do academics stay as adjuncts for years rather than move around? Regardless of the variant of condensate traps, they are always constructed from plastic, similar to other Navien boiler parts which regulate condensate. To learn more, see our tips on writing great answers. Please try again later. Why do small African island nations perform better than African continental nations, considering democracy and human development? There was a problem completing your request. Save my name and email in this browser for the next time I comment. This accessory perfect fit and extension to your dishwasher drain hose, will be needed if your appliance is more than the standard distance away from the house drain. Contractors can save hours of installation by using economical PVC venting and Naviens new Ready-Link Rack system for wall or free standing mounting of multiple units. We might be able to do something about it. Water shouldn't be flowing continuously out of the condensation line, something is wrong somewhere. I bought a home a few months ago that had a Navien tankless water heater installed in 2019. You may need to use a funnel or some other type of container to catch the water as it drains out. Your email address will not be published. Sold by AteliDeals and ships from Amazon Fulfillment. The condensate trap is designed to catch any water that condenses inside the unit. The condensate drain is a small pipe that drains any water that condenses on the heat exchanger. HeyRalph is here! If you have a Navien tankless water heater, you know that one of the most important parts of the unit is the condensate drain fitting. I have a 3 year old Navien 240a tankless water heater. Once the trap is accessible, use a small brush or pipe cleaner to clean out any debris that may be blocking the trap. Please use a different way to share. I have a 5 year old Navien CH240 and it started leaking condensate but from the gasket at the bottom of the heating chamber. Efficient, durable and high-performance products for any commercial application. Click here to Find a Contractor in your area. You may receive a partial or no refund on used, damaged or materially different returns. Our condensate trap is leaking and it looks like the plug is missing an O-ring that would help it seal. Navien tankless water heater CR-240A is leaking Why do many companies reject expired SSL certificates as bugs in bug bounties? To clean the condensate trap, you will need to first shut off the power to the unit. Yesterday I noticed lots of water coming out of the condensate drain. allanlo1973How hard was it to replace the o-ring? Condensation inside Navien tankless water heater Heating Help: The Wall Home Domestic Hot Water Welcome! I think an air gap of some sort is in order. Strange. At this point, the boiler will stop working automatically for safety reasons. Why are physically impossible and logically impossible concepts considered separate in terms of probability? That means it cools the exhaust gas below the boiling point of water, thus causing most of the water vapor there to condense out to liquid. a global leader in high efficiency water heaters and boilers. We also recommend that you report any . NPE 2 Condensing Tankless Water Heaters Navien NPE-2 High Efficiency Condensing Tankless Water Heaters NPE-A2 Series I dont know where to start though. Navien 240a continuous water flow through condensation line Thanks for contributing an answer to Home Improvement Stack Exchange! "After the incident", I started to be more careful not to trip over things. Please make sure that you are posting in the form of a question. The best answers are voted up and rise to the top, Not the answer you're looking for? To fix the problem, simply unplug the unit and allow the water to drain out. Edit: I've spoken to the manufacturer who have zero specs on this. Resources | Partners Login | Become an NSS |Certifications |Parts List | Technical Support | Careers |Global Network |Warranty, All contents copyright Navien Inc. | About Navien |Contact Us | Terms of Use |Privacy Policy |CCPA |Notices, Ultra-high efficiency condensing tankless water heaters, High efficiency non-condensing tankless water heaters. Condensing combi-boilers deliver high-efficiency endless hot water and space heating in one compact unit. Includes initial monthly payment and selected options. Metal-based fittings cannot be used as the condensate itself is a bit acidic in nature and will corrode metal. If the drain is too small, it could become clogged and cause your Navien tankless water heater to malfunction. You talking about the inlet/outlet valve? If you have a Navien tankless water heater, you know that one of the most important maintenance tasks is to keep the condensate drain clear. They said theyve never seen this problem before. Navien Now Doing Business in Canada as Navien Canada, Inc. Navien Begins Shipping PeakFlowC Commercial Scale Prevention Systems. Optional NaviLink Wi-Fi control system gives you access to your Navien systems from anywhere in the world.